Specifications

Chapter 6: FRU Replacement and Fault Isolation Procedures
6-9
6.2.5 Paper Jam in Exit Area of Paper Path: Fault code
E4 continued
4. EXIT ROLL ASSEMBLY ANALYSIS
Use Diagnostic Tool test DG90 to check the Exit Roll Assembly.
Do the Exit Roll and Pinch Roll rotate together?
Yes No
Go to Step 5. Replace the Fuser Assembly.
5. Is the printer equipped with MBF?
Yes No
Go to Step 6. Go to Step 7.
6. ROM DATA ANALYSIS
(E4 appears only when Legal 13" or 14" paper is used)
Does the parameter for Configuration Code A represent the size of the sheets used in the
Front Tray Assembly?
Yes No
Go to Step 10. Correct the parameter.
7. ROM DATA ANALYSIS
(E4 appears only when Legal 13" or 14" paper is used.). Make sure the paper guide is properly
adjusted.
Does the parameter for DG00 SIZE SENSOR represent the actual size of the sheets used
in the Paper Cassette?
Yes No
Go to Step 10. Go to Step 8.
8. ROM DATA ANALYSIS
Make sure the paper guide is properly adjusted.
Do the paper size switches of Feeder PWB or Feeder PWB AUX show the correct switch
combination for the paper size present in the cassette?
Yes No
Go to Section 6.3.13
Paper Size Switch Failure.
Replace the Paper Cassette.