Specifications

Chapter 5: Wiring Diagrams
5-13
LVPS Assembly and the Fuser Assembly
Signal Line Name Signal Line Description
TEMP Thermistor data from the Temperature Sensor
AC N Neutral side of AC input from the AC power source
AC L Line side of AC input from the AC power source
NOTE: Fuse (PL 4.9) opens at 141°C.
Thermostat (PL 4.8) opens at the point of contact temperature of 185°C.
The rated power of the Heater Rod is 280W ±14W (100V Model) and 350W ±17.5W (220V
Model).
The following table shows the Thermistor resistance values at various temperatures.
Thermistor
Temperature
10°C 20°C 30°C 150°C 160°C 170°C 180°C
Resistance in
K
348~526 223~327 146~209 2.9~3.4 2.3~2.6 1.8~2.1 1.4~1.7