Instruction manual
Displaying the Configuration
The "OK" in the DEVSTAT column indicates that the device has
successfully completed the startup test.
Note that some TURBOchannel option modules do not have a
startup test, therefore, no "OK" will appear for them.
In Figure 2–4, a PMAGB-BE module is installed in slot 0, and a
PMAZC-AA is installed in slot 1. These are two TURBOchannel
option modules that may be installed in your system.
What You Need
to Do
Record the information in the TCINFO and DEVNAM columns
for later reference. After adding a module, you can compare the
new system configuration with the previous one to make sure
that all modules are present and functioning correctly.
How to Identify
Errors
If two question marks appear in the DEVSTAT column of the
show config
display, an error has been detected for that module.
If an error indicator appears, as shown in Figure 2–5, follow
these steps:
1. Use the
show error
command, as shown in Figure 2–5, and
note the FRU and error numbers. In this example, the FRU
is 004, and the error number is 0060. The FRU is a field
replaceable unit, a drive or module that can be replaced by
your Digital service representative.
2. Refer to the DEC 3000 Model 800/800S/900 AXP Owner’s
Guide. It will explain how to contact your Digital service
representative.
Preparing to Add Internal Options 2–7