Technical data

Troubleshooting
4-22
Hot Swap Drive Troubleshooting (Model 3220)
Problem Possible Cause Action
Drive fault LED lit. Drive failed. Replace hot swap drive.
Drive activity and fault
LEDs lit.
Drive is hung or has
failed.
Replace hot swap drive.
Drive fault LED flashing. Drive is in recovery
mode or has failed and
is spinning down.
Allow the drive array to build
or fully spin down.
Hot Swap Drive Troubleshooting (Model 3220R)
Problem Possible Cause Action
Drive status LED lit. Drive failed. Replace hot swap drive.
Drive status and fault
status LEDs lit.
Drive is hung or has
failed.
Replace hot swap drive.
Fault status LED
flashing.
Drive is in recovery
mode or has failed and
is spinning down.
Allow drive array to build or
fully spin down.
Disk drive present LED
off.
No drive installed or not
fully seated in the drive
bay.
Reseat the drive or make sure
the installed drive is fully
seated in the drive bay.