Technical data
FRU Replacement
5-59
DIGITAL Server 3220/3220R
Removing and Replacing FRUs (Model 3220R)
The following sections describe how to remove and replace field replaceable units
(FRUs) from the DIGITAL Server 3220R.
Removing and Replacing the Power Supply
1. Turn off
the server
.
2. Remove the front bezel.
3. Remove the two screws securing the server to the rack and then slide it out.
4. Remove the screw securing the top cover to the server.
5. Remove the top cover.
6. Disconnect the power supply cables from the main logic board.
7. Remove the four screws securing the power supply to the chassis.
8. Slide the power supply forward to release it from the chassis.
9. Lift the power supply up and away from the chassis.
10. Replace the power supply by performing the removal steps in reverse order.