User guide

Mode 5 — Factory default reset: With power on, press and hold the reset button
until the reset LED blinks 3 times (~9 seconds). Release then momentarily (<1 second)
press the reset button to return the DMP128 to factory default conditions. If the second
momentary press does not occur within one (1) second, the reset is exited.
The default (reset) state of the device is:
All mix-points are set to 0dB gain and muted
Input 1 is routed to Output 1
Input 2 is routed to Output 2
Input 3 is routed to Output 3
Input 4 is routed to Output 4
Input 5 is routed to Output 5
Input 6 is routed to Output 6
Input 7 is routed to Output 7
Input 8 is routed to Output 8
All outputs active (unmuted, 100% volume).
No inserted or active DSP processing.
All audio inputs are set to 0dB gain and muted.
All preset and group master memory is clear (empty).
Digital I/O Ports
The four 6-pole 3.5 mm captive screw connector Digital I/O ports provide twenty
configurable digital input or output ports designed to connect to various devices such
as motion detectors, alarms, lights, LEDs, buttons, photo (light) sensors, temperature
sensors, relays (requiring ≥30 mA), and others.
All ports are tied to a common ground (one common ground for each 6-pole connector),
but can be individually configured to operate in one of two modes: digital input or digital
output.
The ports are configured using DSPConfigurator. Each port can be configured to monitor
or drive TTL level digital signals (see DigitalI/OPorts on page88).
DMP128 • Installation and Operation 11