Technical data

BIOS and System Programming
72 VIPA GmbH CP486 00/14
4.3.8.2 Bank Interface Registers
The registers must be written in the following order:
Ident register (C800:1F80)
Bank initial register 1 (C800:1F84)
Bank initial register 2 (C800:1F86)
Configuration register (C800:1F82)
Interrupt reset register (C800:1F8E)
Ident Register (Address 0C9F80H):
By means of this register the bank numbers are set up to which the bank interface on PLC side is
responding. If using more than a bank, the entered value must correspond to the each highest bank
number. During the linear operation the value 0 must be transferred.
The register has a width of 8 Bit.
Example 1: eight banks 07 (hex) programming on bank 00 .. 07 (hex)
27 (hex) programming on bank 20 .. 27 (hex)
Example 2: two banks 01 (hex) programming on bank 00 .. 01 (hex)
85 (hex) programming on bank 84 .. 85 (hex)