Technical data
Hardware
CP 486 ⋅ 00/14 VIPA GmbH 27
Setting of DIP Switch S2:
DIP switches 1-3 determine the system configuration if the system SETUP has been lost. The
system configuration is backed up by a Lithium accumulator approx. 6 months. If the module is
stored more than 6 months, then the battery is empty and the filed configuration lost. In this case, a
configuration can be set by means of switches 1-3 to ensure a module startup. The exact
configuration can be loaded by software after the startup.
An empty battery is recharged after approx. 3 days operating time.
4 3 2 1 DIP-switch (default setting in the case of default system configuration)
(battery failure):
off off boot from silicon disk at address C00000 (hex)
off on reserved
on off boot from silicon disk at address 800000 (hex)
on on boot from floppy disk drive A:
off no bank visible towards PLC
on active bank area: bank 32-39
off reserved
on reserved
8 7 6 5 DIP-switch (PCB no. 5012V15, 5012V16, 5012V17):
off off off off VGA monitor with separate Syncs
off off off on RGB monitor (up to VGA-BIOS V11 only graph mode)
off off on off RGB monitor (up to VGA-BIOS V11 only HSync positive)
off off on on RGB monitor (up to VGA-BIOS V11 only HSync negative)
off on off off Finlux-EL display (640*350)
off on off on Hercules, EGA monochrome
off on on off EGA monitor (640*350)
off on on on CGA monitor (80*25)
on on off on CGA monitor (40*25)
on on on off EGA monitor (640*200)
on on on on flat display via additional adapter
6 5 DIP-switch (PCB no. 5012V30, 5012V31, ...)
off VGA monitor with separate Syncs
on RGB monitor
off color (default setup witchout monitor)
on monochrome (default setup witchout monitor)
Delivery status: 1-3:ON, 4-8:OFF