Manual

29
• VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : 90°
TILT ANGLE LIMIT : 07°
SAVE AND EXIT(ESC TO CANCEL)
FLIP OFF, AUTO, 90°, 100°, 110° and 120°
OFF: The dome camera moves until 90° vertically.
AUTO: When the camera reaches the floor directly above the moving object, it will stop.
At that time, pull it down again to run the auto-flip function. When you use the panning range, it is
recommended to use the flip mode to AUTO.
90
°
, 100
°
, 110
°
and 120
°
: Allows the image to flip digitally when the camera moves over the setting
angle vertically.
TILT ANGLE LIMIT -10° ~ 10°
This option is designed to limit the view angle as there is some obstruction in zooming out on specific
areas of the tilt angle.
NOTE: Focus issues may occur in certain conditions.
PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
(CTRL KEY)
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP : OFF
AUTO PAN : ON
SAVE AND EXIT(ESC TO CANCEL)
1. Place the dome camera under 90 degree vertically.
2. Set “RIGHT LIMIT” by pressing the Right key.
3. Set “LEFT LIMIT” by pressing the Left key.
4. Set “ENABLE” to ON to use.
To exchange the right and the left limit, setSWAP” to ON.
To apply limits on the auto pan (endless panning), set “AUTO PAN” to ON.
NOTE: When the flip mode is 90
°
, 100
°
, 110
°
or 120
°
and the camera’s view is manually moved
over 90
°
vertically, the panning range will operate in the opposite side.