Manual

11
NOTE: Open the DIP switch cover and change the setting of the DIP switch as needed.
The cover should be closed after setting DIP switch.
2.4 Setting Dome Camera Address (ID
To prevent damage, each dome camera must have a unique address (ID).
The factory default ID is 1.
Refer to ‘3.9 Dome Communication’ section for detailed information.
2.5 Setting Dome Camera Video Signal & Coaxitron Protocol
S1
You can set the video signal with D1 in S1.
S1-D1 Video Signal
OFF HD-TVI OUTPUT
ON
HD-ANALOG OUTPUT
You can set coaxitron protocol with D2 and D3 in S1.
S1-D2 S1-D3 HD-TVI OUTPUT AHD OUTPUT
OFF OFF TVI-C A_CP-PTZ
ON
OFF Pelco-C Reserved
OFF
ON
Reserved Reserved
ON ON
Reserved Reserved