User Manual

23
2. Set alarm trigger options. The setting steps are the same with that of motion
detection. Please refer to motion detection chapter for details.
3. Click “Save” button to save the settings.
4. Set area and sensitivity of the line crossing alarm. Click “Area and Sensitivity” tab to go
to the interface as shown below.
Set the cordon number and direction. You can add 4 cordons at most.
Direction˖A<->B, A->B and A<-B optional. It is the crossing direction of the intruder who
crosses over the alarm line.
A<->B: The alarm will be triggered when the intruder crosses over the alarm line from B to
A or from A to B.
A->B: The alarm will be triggered when the intruder crosses over the alarm line from A to B.
A<-B: The alarm will be triggered when the intruder crosses over the alarm line from B to A.
Click “Draw” button and then drag the mouse to draw a cordon in the image on the left
side. Click “Stop” button to stop drawing. Click “Clear” button to delete the cordons. Click
“Save” button to save the settings.
5. Set the schedule of the line crossing alarm. The setting steps of the schedule are the
same with that of motion detection. Please refer to motion detection chapter for
details.
Application Scenario Illustration
1. Auto-focusing function should not been enabled for line crossing detection. If enabled,
the video image will change so greatly that the algorithm will stop working temporarily.
2. Try not to enable line crossing detection when light changes greatly in the scene.
3. Try to install the camera at a certain angle of depression.
4. Adequate light and clear scenery are very important to line crossing detection.
5. Adjust the camera to make the detection area in the center of the video image. Make
sure no obstructions are in the main crossing area. It is strongly recommended to make
the obstructions (like trees, bushes, flags, etc.) outside the detection area.
6. Please contact us for more detailed application scenarios.