User Manual
47 | VMAX IP Plus™ NVR
Set a PTZ camera to move to a preset position when the sensor is triggered.
DWELL (Post Alarm)
Set the recoding period from when the sensor is activated. During this period, the selected camera will record according to the record setting. The recording stops
and alarm output is turned off when the set period is completed.
PRE-ALARM
Set recording period in seconds just before a sensor is activated. Input up to 5 seconds. The pre-alarm recording mode is always “continuous” at the recording speed
that user sets in the “Record” menu.
TYPE
Select the sensor type as N/O (Normal Open) or N/C (Normal Close). The circuit of an N/O sensor type is usually open, and the activation of the sensor occurs at
the time of close, and N/C type works the reverse way.
NOTIFY
Enable sensor notification via a buzzer sound and/or a pop-up warning.
Note
When “Camera pop-up” is enabled, in a multi-screen mode, the system will switch to single channel mode automatically when the alarm is triggered.
4.3.2. CAMERA ALARM
Setup the NVR to start recording when motion is detected. The system can also trigger an alarm signal via the selected sensor-out channel.
Note
Check the setting of the sensor type (N/O or N/C). It is recommended to use “Dry Contact Type” while “Wet Contact Type” may cause damage to
the system.