User Manual
Table Of Contents
- 1 Getting Started
- 1.1 Checking Supplied Items
- 1.2 Connecting Peripheral Device
- 1.3 System Startup and Shutdown
- 2 Explanation for Each Function
- 2.1 Front Panel
- 2.2 Rear Panel
- 2.3 IR Remote Controller
- 3 Operation
- 3.1 User Log-in
- 3.2 Quick Startup Wizard
- 3.3 Live Display Mode
- 3.4 PTZ Operation
- 3.5 Call Monitor Operation
- 3.6 Playback of Recorded Video
- 3.7 Quick Backup during Playback
- 3.8 Search Recording Image
- 3.9 DST Setting
- 3.10 Screen Saver
- 4 Setting
- 4.1 System
- 4.2 Device
- 4.3 Record
- 4.4 Network
- 4.5 Backup
- 4.6 Quick Setup
- 5 Web Client
- 5.1 Web Login
- 5.2 Web monitoring
- 5.3 Web Playback
- 5.4 Web Configuration
- 6 Pivot™ User Guide
- 6.1 PC Requirements
- 6.2 Software Installation
- 6.3 Software removal
- 6.4 Basic Operations
- 6.5 Pivot Functions
- 6.6 Pivot Setup
- 7 MAC ACS User Guide
- 7.1 System Requirement
- 7.2 Install
- 7.3 Basic Operation
- 8 Mobile Phone Software User Guide
- 8.1 iPhone application software
- 8.2 Android application software
- 9 Appendix : Network Setup for External Usage
- 10 Appendix : Specification
49 | VMAX960H CORE™ Digital Video Recorder
4.4.1 Health Check
The VMAX960H CORE offers a true DVR health monitoring, with pop-up messages and e-mail notification on video loss,
recording failure, and storage failure.
To setup:
1. Check the box next to "Enable Health Check"
2. Check the box next to the conditions you would like to be notified on.
3. Set the occurrence intervals.(For Example: when video loss occurs more than1 time a minute)
4. Select whether to receive a popup message when conditions are met.
5. Go to Network Notifications.
6. Under e-mail notifications, make sure the Health Check option is enabled.
When any condition occurs beyond the set intervals, the system will display a popup alert and send an e-mail notification.
N
OTE
The system will not send alarm messages or email notification upon motion alarm or sensor unless the
recording schedule is set to record according to that event.
For example, if user sets “Continuous” only for “Schedule Setup” of the “RECORD” menu and marks the
“All” checkbox in “REMOTE NOTIFY”, then the system will not send alarm messages. In this case, user
has to set “C + M”, “MOTION”, “SENSOR” or “C+ S” for REMOTE NOTIFY or E-Mail NOTIFY to function
properly.