User guide

16
7K, 9K series
3.10 LOOPING OUTPUTS
The 8 and 16 Channel DVR units may have up to 16 Looping outputs. Depending on the destination of the
outputs, each output may have to be terminated.
The Video inputs are RG-59 BNC connectors. Make sure there is a video source connected to the input and then
connect a cable to the Channel Out. The looping outs can be connected to video monitors or combined with
adapters to connect to VCR’s.
3.11 LOOPING OUTPUT TERMINATION
When terminating the outputs becomes necessary the DVR unit has built in termination that allows you to select
individual outputs to terminate individually. It is not always necessary to terminate the output when using it. It is
dependant on the device with which you are connecting it to. As a rule, if an image appears distorted or virtually
unviewable, it most likely needs to be terminated.
Always leave the dipswitch set to the ON position when the Looping Outputs are not used.
ON
ON
ON Not connected to a monitor (Normal)
OFF Connected to a monitor (Looped)
1.............................8 9............................16