User guide

15
7K, 9K series
3.8 CONNECTING SENSORS TO THE DVR
Each DVR unit may have up to 16 Sensor inputs. These inputs can be used with devices such as Infrared
devices, motion devise, glass breakage alarms, door and window trips, and many more. The Sensors can be set
to Normally Open or Normally Closed inside the software.
There are 4 Commons (-) and 16 inputs (+). There is no power supplied to the ports so an external power supply
must be used if power becomes necessary.
Normally Open or Normally Closed option is available inside the DVR Software.
There is no power supplied to the ports. Use an external power supply if necessary.
3.9 CONNECTING CONTROL OUTPUTS TO THE DVR
Each DVR unit may have up to 16 Control Outputs. These outputs can be used to trigger devices such as Sirens,
Phone Dialers, Lights, and any other relay activated device.
Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
Maximum voltage is 24V AC @ 1 amp
Output uses a Form C Relay
Sensor Inputs
COM
Sensor (1 ~ 16)
COM Control Out (1 ~ 16)
(+)
(-)
External Power Supply (DC 12V)
Siren, Alarm, Outside Relays