User Manual

DW E.S.T. (Elevated Skin Temperature) System
-27-
10. Specifications
Thermal camera
Sensor
Micro-bolometer Uncooled focal plane array
Resolution 384 x 288
Pixel pitch
17µm
Response wavelength
8µm to 14µm
Thermal sensitivity 50mK@f1.0, 30Hz, 300K
Lens
Lens type Thermalized lens
Focal length 8.13mm f1.16
HFOV/VFOV 47.4°/35.1°
Recommended distance range
for best reliable measurement
6.5 to 16.4ft (2m to 5m). 10ft recommended.
Minimum focus distance 1.64ft (0.5m)
Data
output
Interface Gigabit Ethernet (10/100)
Data Temperature raw data of each pixel of the thermal sensor
Frame rate 30Hz
Visible camera
Sensor
Image sensor 1/3” Progressive CMOS (Approx. 2.1 mega)
Scanning system 16:9 Progressive
Effective pixel 1920 (H) x 1080 (V)
Minimum scene illumination 0.2 lux (color), 0.1 lux (B/W)
Horizontal resolution 1000TVL
Lens Optic 4.0mm 70° HFOV
Video
output
Interface USB3.0 super-speed
Format USB3.0 UVC compliant YUV 422 16bits, uncompressed video
Resolution and frame rate 1920x1080p @ 30fp
General Camera
Operation
Weight 2.2 lbs. (1000 gr.) including USB cable from the visible camera
Dimension (H x W x D) 3.18" x 5.31" x 5.92" (81 x 135 x 150.5mm)
Power supply 12V DC
Operation Temperature
14°F ~ 104°F (-10 ~ 40)
Blackbody
Blackbody
Fixed temperature set at the
factory
104°F (40)
Effective radiant surface
Ф55
Temperature resolution 0.01