User's Manual
Table Of Contents
- 1. What’s in the Box
 - 2. Camera Connection
 - 3. Installation Diagram and Considerations
 - 3.1. Installation Diagram
 - 3.2. Installation Considerations
 - 4. Monitoring PC System Requirements
 - 4.1. Hardware
 - 5. Installation Environment Before Installation
 - 5.1. Check Windows 10 Version
 - 5.2. Windows Update
 - 5.3. Display Setting
 - 5.4. Power and Sleep
 - 6. Software Download and Installation
 - 6.1. Download Software and Camera Network Configuration
 - 6.2. Install the Software
 - 7. Program Installation
 - 8. Software Elements
 - 8.1. Connection Information
 - 8.2. Functions
 - 8.3. Maximum Temperature Indication Window
 - 8.4. Alarm setting
 - 8.5. History
 - 8.6. Top Navigation Bar
 - 8.7. Main Display
 - 8.8. Blackbody Status
 - 8.9. Status
 - 9. Run Program
 - 10. Specifications
 - 11. FAQs
 - 11.1. Usability
 - 11.2. Hardware Related
 - 11.3. Compatibility
 - 11.4. Compliance
 - 12. Warranty Information
 - 13. Limits and Exclusions
 
DW E.S.T. (Elevated Skin Temperature) System 
-4- 
3. Installation Diagram and Considerations 
3.1.  Installation Diagram 
The diagram below represents recommended installation settings. 
1.  Install the camera facing away from the entrance or windows. 
2.  Place the camera 6.5~16.4ft from the objects (10 feet recommended). 
3.  Place the camera at a 20° angle from the objects. 
4.  Make sure people are walking into the camera’s FoV rather than straight towards the camera. 
5.  Only one person in the FoV at a time. 
6.  Place the Blackbody across from the camera, positioned in the corner of the camera’s FoV. 
7.  For optimal readings, the  Blackbody  should be 9.8~14.7ft from the camera  (10 feet 
recommended). 
8.  Recommended room temperature is 68° to 86°F (20° to 30°C). 
9.  Set  up a monitoring station next to the camera with a monitoring PC and personnel. See 
‘Camera Connection’ for more information. 
10.  Always follow elevated temperature readings with additional screening such as a medical 
thermometer and wellness questionnaire. 
For DW-ESTS  installations, where the camera is mounted with a 
Blackbody, allow up to 5 minutes for the camera to power up and 
calibrate properly.   
For DW-ESTCAM installations, where the camera is mounted without 
a Blackbody, allow up to 30 minutes for the camera to power up and 
calibrate properly. 