Web interface - Weather alarm
5.4.5. Weather alarm
The laser sensor is constantly evaluating the measurement signal to determine the weather intensity at a scale from 0
to 10. This allows users to create alarm actions based on weather intensity.
1. In the Alarm settings tab, click on ‘Add alarm’.
2. Select ‘Weather alarm’ from the ‘Input’ drop-down menu.
3. Enter desired threshold level on weather intensity alarm (default is 1).
4. Enter a timeout value, the shortest time the weather alarm is active. Each time the weather intensity
exceeds the threshold, the timeout is reset. Default time is 10 minutes.
5. Press ‘Add’ to save the new alarm.
6. Create Alarm actions for the weather alarm by pressing “+ Add action”.
7. Choose action event type from the drop-down menu options.
Connect to URL
If the weather intensity threshold is exceeded, the unit alarms to the URL.
- Enter desired URL, for example the VMS server.
- Depending on VMS, alarm disable URL can be needed.
Relay action
Activates the internal relay.
Disable reference point
If the weather intensity threshold is exceeded, reference point alarms are ignored.
8. Press the Add action button to confirm settings.