User Manual

Web interface - Login
5. USER INTERFACE
All settings to the sensor can be made through the web-based user interface.
The instructions for the web-based user interface described below are valid for firmware 1.8 and higher.
5.1. FACTORY DEFAULT SETTINGS
When using the sensor for the first time, or if a factory reset has been made, the following settings are used:
Default IP address: 192.168.0.10
Default username: admin
Default password: admin
5.2. LOGIN
1. Open a web browser.
2. In the address field, type in the sensor’s IP address.
3. The web-based user interface login page will be shown.
4. Enter your username and password to access the sensors settings.
5.3. INSTALLATION AND CONFIGURATION
5.3.1. Alignment
1. Alignment is the default tab shown when logging into the sensor.
2. Turn on and o the alignment laser with the buttons on the bottom right. Remember to turn o the laser when
the installation process is complete.
3. The two diagrams on this page show live data from the sensor. The upper diagram shows data from the last 10
seconds. The second data from the last 60 seconds. Each diagram has three curves, representing the highest
value (green), average value (yellow) and lowest value (blue). This means the diagram displays rapid changes
accurately. It is also a good indication of the signal stability. A significant dierence between highest and lowest
values indicates an unstable reference point, such as tree branches.
4. To the right, the screen shows the sensors current distance, highest and lowest distance measured in the last 60
second and the current weather intensity.
11