4. INSTALLATION AND ANGLE ADJUSTMENT
4.1. Alignment
The final alignment adjustment of the sensor is made with the adjustment screws on the side of the sensor. To
facilitate the alignment, horizontal and vertical adjustments must be completed separately.
Vertical
Alignment
Adjustment
Horizontal
Alignment
Adjustment
To align the sensor:
1. Remove the sensors shell.
2. Fasten the telescopic sight (optional) with the quick release mounts.
3. Release all adjustment screws using the included 2.5mm hex Allen wrench.
4. Use the screw on one side to push the sensor in the desired direction. 3/4 turns of the adjustment screws are
equal to 3.28ft (1m) movement at 328ft (100m), 6.56ft (2m) at 656ft (200m) and so on.
5. When the sensor is aligned, tighten the screws from both sides to lock the alignment into place.
6. Confirm that alignment is correct once all the screws have been tightened.
7. Replace the sensor’s shell.
4.2. Hardware reset
1. Remove the sensors shell and service lid.
2. Disconnect the network cable.
3. Press and hold the reset button, while reconnecting the network cable back.
4. Replace the sensor’s service lid and shell.
5. The unit will change its IP address back to the default IP address.
6. When accessing the unit using the web-based user interface, it will load the bootloader screen.
7. If there is any issue with the firmware, please restore factory firmware by pressing ‘Restore factory firmware’.
8. Press ‘Start firmware’ to restart the unit with the factory default IP address and login.
Reset button
Combining the laser sensor with IP cameras