User`s manual
92 • Vacon apfiff09 marine
Tel. +358
6
5= Window control
Speed is limited within window from speed reference.
Speed control activation limit is different from the speed limit. Speed needs, therefore, to
go first to Window Pos or Neg limit before the speed controller activates,
when speed controller is active speed will be restricted
P Window Pos Off
P Window Neg Off
P Pos Freq Limit
P Neg Freq Limit
P Window Neg
P Window Pos
Speed controller active
Speed
Reference
Torque Control
area
Speed controller active
P2.2.9.7 Window negative ID1305
Defines the size of window to negative direction from the final speed reference. If both
windows off limits are zero this parameter is also the speed limit from the
. Otherwise this is the speed control activation limit.
P2.2.9.8 Window positive ID1304
Defines the size of window to positive direction from the final speed reference. If both
windows off limits are zero this parameter is also the speed limit from the
. Otherwise this is the speed control activation limit.
P2.2.9.9 Window negative Off limit ID1307
Defines the speed controller negative off limit when the speed controller brings the
speed back to window.
P2.2.9.10 Window positive Off limit ID1306
Defines speed controller positive off limit when speed controller brings speed back to
window.