P2.2.8.1 Power Reference Selection ID1620
With this parameter the input source for Power Reference is selected. If this value is set
to zero but Torque reference selection is 10=
written directly to Power Reference monitoring value from Fieldbus or with analogue ID
writing function.
- Analogue Input 1.
2.4.3: Input Signals \
- Analogue Input 2.
2.4.4: Input Signals \
2.4.5: Input Signals \
Signal scaling in 2.4.6: Input Signals \
Analogue input 1, -10 Vdc... +10 Vdc
Analogue input 2, -10 Vdc... +10 Vdc
Torque reference from keypad R3.6
Monitoring variable FB Power Reference ID1703
P2.2.8.2 Maximum Power Reference ID1621
Scaling factor for power reference input. Scaling is not used when Power reference
selection is 7 or 8.
P2.2.8.3 Power reference increase rate ID1621
Ramp up rate for power reference. Ramping rate does not have an effect when reference
is decreased. When ramp rate is set to zero ramping is bypassed.
Input
reference
Power
Reference
80 %
20 %
Internal
reference
10 % / s
6 s