User`s manual

apfiff09 marine vacon • 75
24-
5
6.18 Keypad control (Control keypad: Menu M3)
The parameters for the selection of control place and direction on the keypad are listed
below. See the Keypad control menu in the Vacon NX User's Manual.
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P3.1
Control place
1
3
2
125
0=PC Control
1=I/O terminal
2=Keypad
3=Fieldbus
R3.2
Keypad reference
P2.1.1
P2.1.2
Hz
0,00
P3.3
Direction (on
keypad)
0
1
0
123
0=Forward
1=Reverse
P3.4
Stop button
0
1
1
114
0=Limited function of Stop
button
1=Stop button always
enabled
R3.5
Torque reference
0,0
100,0
%
0,0
Table 6-47. Keypad control parameters, M3
6.19 System menu (Control keypad: Menu M6)
For parameters and functions related to the general use of the frequency converter, such as
application and language selection, customised parameter sets or information about the
hardware and software, see Chapter 7.3.6 in the Vacon NX User's Manual.
6.20 Expander boards (Control keypad: Menu M7)
The M7 menu shows the expander and option boards attached to the control board and
board-related information. For more information, see Chapter 7.3.7 in the Vacon NX User's
Manual.