User`s manual

74 • Vacon apfiff09 marine
Tel. +358
5
6.16 Autorestart parameters
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.16.1
Wait time
0,10
10,00
s
0,50
717
P2.16.2
Trial time
0,00
60,00
s
0,10
718
P2.16.3
Start function
0
2
2
719
0=Ramp
1=Flying start
2=According to Stop
Function
P2.16.4
Number of tries after
undervoltage trip
0
10
0
720
P2.16.5
Number of tries after
overvoltage trip
0
10
0
721
P2.16.6
Number of tries after
overcurrent trip
0
3
0
722
P2.16.7
Number of tries after
reference trip
0
10
0
723
P2.16.8
Number of tries after
motor temperature
fault trip
0
10
0
726
P2.16.9
Number of tries after
external fault trip
0
10
0
725
P2.16.10
Number of tries after
underload fault trip
0
10
0
738
P2.16.11
Fault Simulation
0
65535
0
1569
Table 6-45. Autorestart parameters, G2.16
6.17 PI Control Parameters
Code
Parameter
Min
Max
Unit
Step
Default
ID
Note
P2.17.1
PI controller gain
0,0
1000,0
%
100,0
118
P2.17.2
PI controller I-
time
0,00
320,00
s
1,00
119
P2.17.3
PI Reference
-32000
32000
0
167
P2.17.4
PI controller
reference signal
ID
0
10000
167
332
Default P2.17.3
P2.17.5
PI Actual value ID
0
10000
0
333
P2.17.6
PI Controller
output ID
0
10000
0
1802
P2.17.7
PI Controller
Scale
-32000
32000
1
340
>= 1 = No inversion
<=-1 = Inverted
0 = Illegal value
P2.17.8
PI Low limit
-32000
32000
359
P2.17.9
PI High limit
-32000
32000
10000
360
P2.17.10
PI Controller
Output scale
-3200,0
3200,0
%
100,0
1803
P2.17.11
PI Stop state value
-32000
32000
0
1806
Table 46. PI Controller parameters, G2.15