User`s manual

apfiff09 marine vacon • 73
24-
5
6.15 Brake Control
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.15.1
BrakeMechDelay
0,00
320,00
s
0,00
1544
Time that is required to
open the brake
P2.15.2
Brake OFF FreqLim
Open Loop
0,00
320,00
Hz
1,50
1535
Opening limit and
maximum reference
limit when brake is
closed.
P2.15.3
Brake OFF FreqLim
Closed Loop
0,00
320,00
Hz
0,00
1555
Opening limit and
maximum reference
limit when brake is
closed.
P2.15.4
Brake ON FreqLim +
0,00
320,00
Hz
1,00
1539
Close frequency from
positive direction
P2.15.5
Brake ON FreqLim -
0,00
320,00
Hz
1,50
1540
Close frequency from
negative direction
P2.15.6
Brake On/Off
Current Limit
0,00
320,00
A
0,00
1085
Brake is closed
immediately id current
goes below this value.
P2.15.7
Generator Torque
limit increase speed
level
0,00
320,00
Hz
0,00
1547
Function disabled when
zero. Point where
Generator torque limit
stars to increase.
P2.15.8
Generator Torque
limit increase
maximum speed
limit
0,00
320,00
Hz
100,00
1548
Point where torque
value of ID1549 is added
to base generator torque
limit.
P2.15.9
Generator Torque
limit increase
maximum addition
0,0
300,0
%
300,0
1549
P2.15.10
Brake Fault Action
1
3
1
1316
1=Warning
2=Fault,stop acc. to 2.3.2
3=Fault,stop by coasting
P2.15.11
Brake Fault Delay
0,00
320,00
s
0,20
1317
Table 6-44. Brake control parameters, G2.3.9
6.15.1.1
Brake Control Start up torque for CL
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.15.12.1
Start-up torque
0
3
0
621
0=Not used
1=Torque memory
2=Torque reference
3=Start-up torque fwd/rev
P2.15.12.2
Start-up torque FWD
300,0
300,0
s
0,0
633
P2.15.12.3
Start-up torque REV
300,0
300,0
s
0,0
634
P2.15.12.4
Start Up Torque Time
-1
10000
ms
-1
1371
-1 = Automatic
6.15.1.2
Roll Back Control for CL
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.15.13.1
Roll Back Kp
1787
P2.15.13.2
Roll Back Torque
1788
P2.15.13.3
Roll Back Level
1789