User`s manual
apfiff09 marine vacon • 71
24-
5
6.14 ID Control Functions
6.14.1
Value Control
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.14.1.1
Control Input Signal
ID
0
10000
ID
0
1580
P2.14.1.2
Control Input Off
Limit
-32000
32000
0
1581
P2.14.1.3
Control Input On
Limit
-32000
32000
0
1582
P2.14.1.4
Control Output Off
Value
-32000
32000
0
1583
P2.14.1.5
Control Output On
Value
-32000
32000
0
1584
P2.14.1.6
Control Output Signal
ID
0
10000
ID
0
1585
P2.14.1.7
Control Mode
0
5
0
1586
0=SR ABS
1=Scale ABS
2=Scale INV ABS
3=SR
4=Scale
5=Scale INV
P2.14.1.8
Control Output
Filtering rime
0,000
32,000
s
0,000
1721
Table 6-37. Power reference input signal selection, G2.2.8
6.14.2
DIN ID Control 1
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.14.2.1
ID Control DIN
0.1
E.10
0.1
1570
Slot . Board input No.
P2.14.2.2
Controlled ID
0
10000
ID
0
1571
Select ID that is
controlled by digital input
P2.14.2.3
False value
-32000
32000
0
1572
Value when DI is low
P2.14.2.4
True value
-32000
32000
0
1573
Value when DI is high
Table 6-38. DIN ID Control parameters
6.14.3
DIN ID Control 2
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.14.3.1
ID Control DIN
0.1
E.10
0.1
1590
Slot . Board input No.
P2.14.3.2
Controlled ID
0
10000
ID
0
1575
Select ID that is
controlled by digital input
P2.14.3.3
False value
-32000
32000
0
1592
Value when DI is low
P2.14.3.4
True value
-32000
32000
0
1593
Value when DI is high
Table 6-39. DIN ID Control parameters
6.14.4
DIN ID Control 3
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.14.4.1
ID Control DIN
0.1
E.10
0.1
1578
Slot . Board input No.
P2.14.4.2
Controlled ID
0
10000
ID
0
1579
Select ID that is
controlled by digital input
P2.14.4.3
False value
-32000
32000
0
1594
Value when DI is low
P2.14.4.4
True value
-32000
32000
0
1596
Value when DI is high
Table 6-40. DIN ID Control parameters