56 • Vacon apfiff09 marine
Tel. +358
5
6.7 Flux and DC Current handling
6.7.1
Flux and DC Current handling OL Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.7.1.1
DC braking current
0,00
I
L
A
0,00
507
P2.7.1.2
DC braking time
at start
0,00
600,00
s
0,00
516
0=DC brake is off at start
P2.7.1.3
DC braking time
at stop
0,00
600,00
s
0,00
508
0=DC brake is off at stop
P2.7.1.4
Frequency to start DC
braking during
ramp stop
0,10
10,00
Hz
1,50
515
P2.7.1.5
Scaling of DC-braking
current
0
5
0
400
ID46Scaling from 0 to ID507
0=Not used
1=AI1
2=AI2
3=AI3
4=AI4
5=FB Limit Scaling
P2.7.1.6
DC-Brake Current in
Stop
0,00
I
L
A
Varies
1080
P2.7.1.7
Flux brake
0
1
0
520
0=Off
1=On
P2.7.1.8
Flux braking current
0,00
I
L
A
I
H
519
6.7.2
Flux and DC Current handling CL Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.7.2.1
Magnetizing current at
start
0
I
L
A
0,00
627
P2.7.2.2
Magnetizing time at
start
0,0
600,0
s
0,0
628
P2.7.2.3
Flux Reference
0,0
500,0
%
100,0
1250
P2.7.2.4
Flux Off Delay
-1
32000
s
0
1402
-1=forever
P2.7.2.5
Stop State Flux
0,0
150,0
%
100,0
1401
P2.7.2.6
Reduced Flux Level
0,0
500,0
%
100,0
1613
P2.7.2.7
Reduced Flux
Frequency
0,00
32,00
Hz
0,00
1614