User`s manual
54 • Vacon apfiff09 marine
Tel. +358
5
6.6.3
Torque Handling
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.6.3.1
Torque Limit
0,0
300,0
%
300,0
609
General maximum limit
P2.6.3.2
Motoring Torque Limit
0,0
300,0
%
300,0
1287
Motoring side torque limit
P2.6.3.3
Generator Torque
Limit
0,0
300,0
%
300,0
1288
Generator side torque limit
P2.6.3.4
Motoring Torque Limit
1
0,0
300,0
%
300,0
1625
P2.6.3.5
Generator Torque limit
1
0,0
300,0
%
300,0
1627
P2.6.3.6
Torque Follower
0
1
0
1706
0 = No
1 = Yes
P2.6.3.7
Torque limit increase
rate
0
10000
%/s
100
1532
P2.6.3.8
Torque limit follower
hysteresis
0,0
300,0
%
10,0
1533
P2.6.3.9
Scaling Motoring
Torque limit
0
5
0
485
Scaling from 0 to ID1287
0=Not used
1=AI1
2=AI2
3=AI3
4=AI4
5=FB Limit Scaling ID46
P2.6.3.1
0
Scaling Generator
Torque limit
0
5
0
1087
Scaling from 0 to ID1288
As parameter P2.6.3.9
6.6.3.1
Torque Handling OL Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.6.3.9.1
Torque limit control
P-gain
0,0
32000
3000
610
P2.6.3.9.2
Torque limit control
I-gain
0,0
32000
200
611
6.6.3.2
Torque Handling CL Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.6.3.10.1
SPC Out Limit
0,0
300,0
%
300,0
1382
P2.6.3.22
SPC Pos Limit
0,0
300,0
%
300,0
646
P2.6.3.21
SPC Neg Limit
0,0
300,0
%
300,0
645
6.6.4
Frequency Handling
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.6.4.1
Max Frequency 2
0,00
320,00
Hz
35,00
1512
Maximum frequency limit
that is activated by digital
input.
P2.6.4.2
Negative frequency
limit
-320,00
320,00
Hz
-320,00
1286
Alternative limit for negative
direction
P2.6.4.3
Positive frequency
limit
-320,00
320,00
Hz
320,00
1285
Alternative limit for positive
direction
P2.6.4.4
Zero Frequency
limit
0,00
320,00
Hz
1,00
1283