User`s manual

46 • Vacon apfiff09 marine
Tel. +358
5
6.4.4
Analogue input 2
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.4.4.1
AI2 signal selection
0.1
E.10
A.2
388
Slot . Board input No.
P2.4.4.2
AI2 filter time
0,000
32,000
s
0,000
329
0=No filtering
P2.4.4.3
AI2 signal range
0
3
1
325
0
1
2= -
3= Custom range*
P2.4.4.4
AI2 custom
minimum setting
-160,00
160,00
%
0,00
326
Custom Range:
Minimum input
P2.4.4.5
AI2 custom
maximum setting
-160,00
160,00
%
100,00
327
Custom Range:
Maximum input
P2.4.4.6
AI2 reference
scaling, minimum
value
0,00
320,00
Hz
0,00
393
Selects the frequency that
corresponds to the min.
reference signal
P2.4.4.7
AI2 reference
scaling, maximum
value
0,00
320,00
Hz
0,00
394
Selects the frequency that
corresponds to the max.
reference signal
P2.4.4.8
AI2 joystick Dead
Zone
0,00
20,00
%
0,00
395
Dead Zone for joystick
input
P2.4.4.9
AI2 sleep limit
0,00
100,00
%
0,00
396
Drive goest to stop if input
is below this limit for this
time.
P2.4.4.10
AI2 sleep delay
0,00
320,00
s
0,00
397
P2.4.4.11
AI2 joystick offset
-100,00
100,00
%
0,00
166
Press enter for 1s to set
offset
Table 6-8. Analogue input 2 parameters, G2.2.3
6.4.5
Analogue input 3
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.4.5.1
AI3 signal selection
0.1
E.10
0.1
141
Slot . Board input No.
If 0.1 ID27 can be
controlled from FB
P2.4.5.2
AI3 filter time
0,000
32,000
s
0,000
142
0=No filtering
P2.4.5.3
AI3 custom
minimum setting
-160,00
160,00
%
0,00
144
Custom range always
active. See ID326
P2.4.5.4
AI3 custom
maximum setting
-160,00
160,00
%
100,00
145
Custom range always
active. See ID327
P2.4.5.5
AI3 signal inversion
0
1
0
151
0=Not inverted
1=Inverted
P2.4.5.6
AI3 reference
scaling, minimum
value
-32000
32000
0
1037
Selects the value that
corresponds to the min.
reference signal
P2.4.5.7
AI3 reference
scaling, maximum
value
-32000
32000
0
1038
Selects the value that
corresponds to the max.
reference signal
P2.4.5.8
AI3 Controlled ID
0
10000
0
1509
Select parameter that
you want to control by ID
number.
Table 6-9. Analogue input 3 parameters, G2.2.4
**Remember to place jumpers of block X2 accordingly.
See NX User's Manual, chapter 6.2.2.2