User`s manual

240 Vacon apfiff09 marine
Tel. +358
6
B08: FALSE = No Function, TRUE = Jogging 1
Inching 1: Drive follows reference set by Jogging Ref 1. Function needs to separately activated by
Aux Control Word or by digital input Enable Jogging when IO control used for Jogging.
B09: FALSE = No Function, TRUE = Inching 2
Inching 2: Drive follows reference set by Jogging Ref 2. Function needs to separately activated by
Aux Control Word or by digital input Enable Jogging when IO control used for Jogging.
B10: FALSE = FB Control disabled TRUE = FB Control Enabled
FB Control Disabled: Drive will not follow main control word from Fieldbus. If removed while
running drive will make coasting stop.
FB Control Enabled: Drive follows control word from fieldbus
B11: FALSE = FB WD Pulse Low, TRUE = FB WD Pulse High
Watch dog pulse: This pulse is used to monitor that PLC is alive. If pulse is missing drive will go to
fault state. This function is activated by P2.12.10.3 FB WD Delay. When value is zero pulse is not
monitored.