User`s manual
230 • Vacon apfiff09 marine
Tel. +358
6
7.18 Keypad control parameters
Unlike the parameters listed above, these parameters are located in the M3 menu of the control
keypad. The reference parameters do not have an ID number.
P3.1 Control Place ID125
The active control place can be changed with this parameter.
Pushing the Start button for 3 seconds selects the control keypad as the active control
place and copies the Run status information (Run/Stop, direction and reference).
0 = PC Control, Activeted by NCDrive
1 = I/O terminal
2 = Keypad
3 = Fieldbus
R3.2 Keypad Reference No ID
The frequency reference can be adjusted from the keypad with this parameter.
The output frequency can be copied as the keypad reference by pushing the Stop button
for 3 seconds when you are on any of the pages of menu
M3.
P3.3 Keypad Direction ID123
0 Forward: The rotation of the motor is forward, when the keypad is the active
control place.
1 Reverse: The rotation of the motor is reversed, when the keypad is the active
control place.
P3.4 Stop button activated ID114
If you wish to make the Stop button a "hotspot" which always stops the drive regardless
of the selected control place, give this parameter the value 1.
R3.5 Torque reference No ID
R3.5 Power reference No ID
Define here the power