User`s manual
apfiff09 marine vacon • 215
24-
6
1 = Scale ABS
Absolute input value is scaled linearly between On and Off values.
Off
value
On
value
Control
Off
value
Control
On
Value
Off
value
On
value
Negative Positive
2 = Scale ABS Inverted
Inverted absolute value is scaled linearly between On and Off values.
Off
value
On
value
Control
Off
value
Control
On
Value
Off
value
On
value
Negative Positive
3 = SR
Input value is used to make a step change in the output between On and Off values.
4 = Scale
Input value is scaled linearly between On and Off values.
5 = Scale Inverted
Inverted value is scaled linearly between On and Off values
P2.14.1.8 Control Signal Filtering TC ID1586
This parameter is used to filter the scaling function output. Used e.g. when unfiltered
torque is used to control a parameter that needs stabilization.