P2.13.3 to
P2.13.10 Fieldbus data out selections 1 to 8 ID852-
Using these parameters, you can monitor any monitoring or parameter value from the
fieldbus. Enter the ID number of the item you wish to monitor for the value of these
parameters. See monitoring signals for full details of ID numbers.
Default settings:
Data
Value
Unit
Scale
ID
Status Word
Main Status Word
FB General Status
Word
MCStatus
64
FB Actual Speed
Actual Speed
%
0,01 %
Process data OUT 1
Output Frequency
Hz
0,01 Hz
1
Process data OUT 2
Motor Speed
rpm
1 rpm
2
Process data OUT 3
Motor Current
A
0,1 A
45
Process data OUT 4
Motor Torque
%
0,1 %
4
Process data OUT 5
Motor Power
%
0,1 %
5
Process data OUT 6
Motor Voltage
V
0,1 V
6
Process data OUT 7
DC link voltage
V
1 V
7
Process data OUT 8
Active Fault Code
-
-
37
P2.13.11 to
P2.13.18 Fieldbus data IN selections 1 to 8 ID876-833
Using these parameters, you can control any monitoring or parameter value from the
fieldbus. Enter the ID number of the item you wish to control for the value of these
parameters. Monitoring signals that can be controlled from fieldbus are shadowed.
Default settings:
Data
Value
Unit
Scale
ID
Reference
Speed Reference
%
0.01%
-
Control Word
Main Control Word
-
-
-
Control Word 2
General Control Word
Process Data IN1
Torque Reference
%
0.1%
1140
Process Data IN2
Free Analogue INPUT
%
0.01%
46
Process Data IN3
Adjust Input
%
0.01%
47
Process Data IN4
FB Analogue Output
%
0.01%
48
PD4 PD8
Not Used
-
-
-
P2.13.19 Fieldbus General Status Word ID ID897
With this parameter it is possible to select which data are sent in FBGeneralStatusWord
(see for details and availability in used fieldbus manual).