User`s manual
apfiff09 marine vacon • 193
24-
6
P2.11.7 SystemBus communication fault response ID1082
Defines the action when the System Bus heartbeat is missing.
The master drive sends a heartbeat signal to all follower drives and this heartbeat is
sent back to the master drive.
0 = No response
1 = Warning
2 = Fault, stop mode after fault according to Stop function
3 = Fault, stop mode after fault always by coasting
P2.11.8 Systembus fault delay ID1352
Defines the delay before fault generation when heartbeat is missing.
P2.11.9 Follower Fault ID1536
Defines the response in the Master drive when a fault occurs in any of the follower
drives. When one of the drives trips to fault the master drive will send a command to
trigger the Data Logger in all the drives for diagnostic purposes.
0 = No response
1 = Warning
2 = Fault, stop mode after fault according to Stop function
7.11.3.1
Drive Synch Control parameters
P2.11.10.1 DriveSynch Follower Fault ID1531
Defines the response in the Master drive when a fault occurs in any of the follower
drives. When one of the drives trips to fault the master drive will send a command to
trigger the Data Logger in all the drives for diagnostic purposes.
0 = No response
1 = Warning
2 = Fault, stop mode after fault according to Stop function
P2.11.10.2 Follower drive winding phase shift ID1518
Windings phase shift between master and follower drive. Used with drive synch
operation when the motor has multiple windings.
P2.11.10.3 DC Voltage balancing gain ID519
Multiple wind motor option. Contact factory before changing this value.
P2.11.10.4 SB Last ID 2nd ID1799
With this parameter is possible to change last ID number of the drive from fieldbus.