User`s manual

apfiff09 marine vacon • 19
24-
5
V1.5 Motor torque % ID 4
In % of Motor nominal torque
Open loop
1 s linear filtering
Closed Loop
32 ms filtering
Drive Synch Operation Follower drive
nominal current.
V1.6 Motor Power % ID 5
Calculated motor power
V1.7 Motor voltage V ID 6
Calculated motor voltage
V1.8 DC link voltage V ID 7
Measured DC voltage, filtered.
V1.9 Unit temperature ID 8
Heatsink temperature
V1.10 Motor temperature % ID 9
Calculated motor temperature
105 % is tripping limit if response is fault.
V1.11 Analogue input 1 % ID 13
V1.12 Analogue input 2 % ID 14
Unfiltered analogue input level.
0 % = 0 mA / 0 V, -100 % = -10 V, 100 % = 20 mA / 10 V.
Monitoring scaling is determined by the option board parameter.
V1.13 Analogue input 3 % ID 27
V1.14 Analogue input 4 % ID 28
It is possible to adjust this input value from fieldbus when the input terminal
selection is 0.1. This way it is possible to adjust the free analogue input from
fieldbus and have all analogue input functions available for fieldbus process
data.