User`s manual
apfiff09 marine vacon • 185
24-
6
and below this a normal U/f curve is used. The activation of this selection
requires a performed identification with run.
B09 = I/f control for PMS motors. PMS motor can be started with I/f control. Used with
high power motor when there is low resistance in motor and U/f is difficult to
tune to be stable.
B13 = Changes automatically depending on Drive Synch operation
P2.10.7 Advanced Options 4 ID1563
Reserved for future use. Some bits are controlled by application software so value may
not be always zero.
P2.10.8 Advanced Options 5 ID1564
Reserved for future use. Some bits are controlled by application software so value may
not be always zero.
P2.10.9 Advanced Options 6 ID1565
B05 = To reduce aliasing effects in current measurement, it is possible to take an
average from all internal samples taken at fast time level. It must be noted, that
this mode does not affect the motor control, only monitoring.
P2.10.10 Restart Delay ID1424
The time delay within which the drive cannot be restarted after a coast stop and flying
start is not in use. Closed Loop control mode and the flying start use a different delay
see P2.9.11.
P2.10.11 Restart Delay Closed Loop & Flying Start ID672
The time delay within which the drive cannot be restarted if flying start is used or the
control mode is closed loop.