User`s manual
apfiff09 marine vacon • 175
24-
6
7.8.6
Identification settings
P2.8.8.1 to
P2.8.8.15 ID1355 ID1369
Flux voltage. Measured during identification.
P2.8.8.16 Measured Rs voltage drop ID662
The measured voltage drop at stator resistance between two phases with the nominal
current of the motor. This parameter is identified during identification run.
This parameter defines the motor stator resistance as a voltage drop at nominal current.
The parameter value is defined according to motor nominal voltage and the current and
the actual stator resistance as
.
P2.8.8.17 Ir: Add zero point voltage ID664
Defines how much voltage is applied to motor in zero speed when torque boost is used.
P2.8.8.18 Ir: Add generator scale ID665
Defines the scaling factor for generator side IR-compensation when torque boost is
used.
P2.8.8.19 Ir: Add motoring scale ID667
Defines the scaling factor for motoring side IR-compensation when torque boost is used.
P2.8.8.20 Measured Ls voltage drop ID673
Leakage inductance voltage drop with nominal current and frequency of the motor. This
parameter defines the Ls voltage drop between two phases. Use identification run to
determine the optimum setting.
P2.8.8.21 Motor BEM Voltage ID674
Motor-induced back voltage.
P2.8.8.22 IU Offset ID668
P2.8.8.23 IV Offset ID669
P2.8.9.24 IW Offset ID670
Offsets the value for phase current measurement. Identified during identification run.
P2.8.8.25 Estimator Kp ID1782
Estimator gain for PMS motor. Identified during identification run.