P2.6.5.8.3 CL Under Voltage Reference
Defines the under votlage reference level in Closed Loop control mode. Percentage value
related to unit nominal voltage DC voltage. Default 65 %.
690 Vac * 1,35 * 65 % = 605 Vdc
500 Vac * 1,35 * 65 % = 438 Vdc
7.6.6
Limit options
P2.6.6.1 Limit total current ID1901
This function activates the total current limit function in close loop control. Normally in
closed loop the current limit only affects the torque producing current.