User`s manual
apfiff09 marine vacon • 115
24-
6
P2.4.3.4 AI1 custom minimum setting ID321
P2.4.3.5 AI1 custom maximum setting ID322
P2.4.4.4 AI2 custom minimum setting ID326
P2.4.4.5 AI2 custom maximum setting ID327
These parameters set the analogue input signal for any input signal span within -160...160%. E.g.
if the signal input scaling is set to 40 %...80 % the reference can be changed from 8 mA
(for Minimum Frequency) to 16 mA (for Maximum Frequency).
P2.4.3.6 AI1 Reference scaling, minimum value ID303
P2.4.3.7 AI1 Reference scaling, maximum value ID304
P2.4.4.6 AI2 reference scaling, minimum value ID393
P2.4.4.7 AI2 reference scaling, maximum value ID394
Additional reference scaling. Analogue input reference scaling can be set to a different
value than the minimum and maximum frequency.
Reference [Hz]
Analogue
Input
100 %
0 %
Min Freq
0 Hz
Max Freq
60 Hz
47 Hz
Ref Scale
Max
24 Hz
Ref Scale
Min
Reference [Hz]
Analogue
Input
100 %
0 %
Min Freq
0 Hz
Max Freq
60 Hz
47 Hz
Ref Scale
Max
24 Hz
Ref Scale
Min
40 %
Custom
Min
80 %
Custom
Max
P2.4.3.8 Analogue Input 1 joystick input dead zone ID382 1
P2.4.4.8 Analogue Input 2 joystick input dead zone ID395
The small values of the reference around zero can be ignored by setting this value
greater than zero. When the reference lies between zero and ± this parameter, it is
forced to zero.
+10 V
+100 %
Max Freq
- Max Freq
Analogue Input
Reference
-10 V
-100 %
+10 %
-10 %
AI Joystick
DeadZone
= 10 %