User`s manual

110 Vacon apfiff09 marine
Tel. +358
6
P2.4.2.28 Motoring Power limit Digital input 1 ID1500
P2.4.2.29 Motoring Power limit Digital input 2 ID1501
With this parameter you can select the desired digital input for controlling motoring
power limit. activates respective power
limits defined in parameter group G2.6.2 Power Handling. If both inputs are activated
power limit is zero.
P Motoring power limit 1
P Motoring power limit 2
SEL4
B0
B1
IN00
IN01
IN10
IN11
F Power limit zero
P Motoring power limit
DI Motoring power limit 1
DI Motoring power limit 2
Limit for ramping control
P2.4.2.30 Digital input 2
nd
Frequency Limit ID1511
With this parameter you can select the digital input that will limit the maximum
frequency to a lower value than what is defined by Maximum Frequency. This limit does
not affect any constant references. The limit is set in G2.6.4 Freq. Limit Handling.
P2.4.2.31 Generator Power limit Digital input 1 ID1506
P2.4.2.32 Generator Power limit Digital input 2 ID1507
With these parameters you can select the desired digital input for controlling the
the
respective power limits defined in G2.6.2 Power Handling parameter group. If both inputs
are activated power limit is zero.
P Generator power limit 1
P Generator power limit 2
SEL4
B0
B1
IN00
IN01
IN10
IN11
F Power limit zero
P Generator power limit
DI Generator power limit 1
DI Generator power limit 2
Limit for ramping control
P2.4.2.33 Reset encoder counter ID1090
When using encoder, the drive monitors the encoder rotations and angle (V: Shaft
Rounds and V:Shaft Angle).
When this input has a rising edge monitoring values V:Shaft Angle (ID1169) and Shaft
Rounds (ID1170) are set to zero. Reset command is also included in V: Aux Control Word.
P2.4.2.34 Master Follower mode 2 ID1092
Master Follower mode can be changed with digital input between P2.10.1 MF Mode and
P2.10.5: MF Mode 2 in the Master Follower parameter group. This can be used for
redundancy purposes e.g. when using a Drive Synch system.
SEL
G
IN 0
IN 1
DI MF Mode 2
P MF Mode 1
P MF Mode 2
Used MF Mode