User`s manual

apfiff09 marine vacon • 107
24-
6
P2.4.2.9 Motor potentiometer UP ID418
Contact closed: Motor potentiometer reference DECREASES until the contact is
opened. See details in G2.2.11 Motor Pot.
P2.4.2.10 Fault reset ID414
Rising edge required to reset fault.
P2.4.2.11 External fault closing contactor ID405
External fault input closing contactor, response selected in protection parameter group
G2.11.1 Protections / General.
P2.4.2.12 External fault opening contactor ID406
External fault input opening contactor, response selected in protection parameter group.
P2.4.2.13 Acceleration/Deceleration time selection ID408
parameter group.
Contact open: Acceleration/Deceleration time 1 selected
Contact closed: Acceleration/Deceleration time 2 selected
P2.4.2.14 Acceleration/Deceleration prohibited ID415
Contact closed: No acceleration or deceleration possible until the contact is opened.
With P2.9.3 Control Options B13 is possible to select that deceleration direction is
allowed thus speed is reduced if reference is smaller that drive speed at the time.
P2.4.2.15 DC-braking command ID416
Contact closed: In STOP mode, the DC braking operates until the contact is opened.
Current level is set with P2.7.1.16 DCBrakeCurInStop parameter.
P2.4.2.16 Jogging speed ID413
Contact closed: Jogging speed selected for frequency reference
Reference for jogging speed is set in G2.2.7 Constant Reference group.
P2.4.2.16 I/O Reference 1/2 selection ID422
With this parameter you can select either AI1 or AI2 signal for frequency reference if I/O
reference selection is 14 / AI1/AI2 Se .
If selection for P2.2.1
change reference between P2.2.1 I/O Reference and P2.2.4 I/O Reference 2.