User`s manual
VC-55™ PR Voice Codec Board
User’s Manual
Version 1.3
Section 3 – Set-up & Control
Page 12
DVSI Confidential Proprietary
suppression (NS) and silence frame
generation (DTX) in the encoder
4096 Enables Tone Detection.
Audio Options
[l]ine
Sets the audio input source to the
stereo line in Jack J2
-i
Analog Voice Input Source
[h]andset
Sets the audio input source to the
Handset (RJ11) Jack J5
Table 5 vc55param variables
Notes:
1) Changes to EncodeModePinEnable, EncodeMode, SlipMode, ChanRxMinTime, and
ChanRxMaxTime take effect the next frame.
2) Changes to EncodeSource, EncodeCmode, SideTone, ChannelUartRate require Flash
and reset to take effect.
3) To program settings into flash you have to enter the parameters to change along with
the –F option.
Example: To set the baud rate 28,800 into the memory the correct command is
vc55param –c 80 –F
then verify the data by running vc55param (with no command line options) twice (SEE
NOTE BELOW)
vc55param
vc55param
Once you do this and reset the board it will remain in memory.
NOTE: When running the vc55param program for the first time after a reset or after
applying power, the settings printed out to screen may contain erroneous data.
Therefore, it is always best to run vc55param a couple of times (with no command line
options) before verifying the actual parameter settings as set in flash.
Running the Program
The vc55param is run from a DOS window. Go to the directory that contains the vc55param.exe file
and type in vc55param the program will run and print to screen the current status of the board. The
response will contain the following items:
Parameter Option Name Variable Description
vc55 Status Device=0
This is a device number identification. If two or more VC-55s are
connected to USB ports at the same time then the vc55param
program will write to both devices. This is useful if you want to bulk
load the same parameters or see the settings for all boards.
However, when more than one board is connected to a USB you do
not have individual control of setting different parameters for each