3. ERROR CODES
Code On screen message Description
0 ERROR Generic error
1 FAN SLOW Fan fault, fan too slow
2 LAMP HOT Lamp too hot (>= 80 C)
3 PSU HOT Dimmer board too hot (IRQ, over 80...85 C)
4 WRONGLAMP Unsupported lamp type, likely a new release
5 CABLE ERR Cable error
6 ACDC ERR AC/DC error
7 1-WIRE ERR 1-Wire error (unable to communicate with lamp unit)
Error codes
Critical/blocking codes; the device attempts to clear these every 30 seconds.
A manual attempt to clear the error can also be made on the DS1 from a single device or
Master (topmost) device in a stack, by pressing OK when the code is on screen. But when
the problem persists the code reappears immediately.