User Guide

17
DS1 User Manual
2. CONTROL / Color page / Color control
Please note that ITSH settings will be
recorded after 6 seconds after manual in-
put and after five minutes when consis-
tent DMX values are sent by an external
controller. These will be the starting ITSH
settings after PSU reboot.
When DMX communication is active and
DMX packet values are changing constant-
ly (light animation) the ITSH values are not
saved.
It is possible to control the PSU manually
from the control panel of the PSU while
wired DMX or ArtNet is active but please
remember, the control will be transferred
back to the active remote device after 30
seconds, which means ITSH parameters
will change to those of the remote control-
ler.
Make sure to switch off the remote
mode under “REMOTE” in the Setup
menu if you intend to control your
lights from the power supply.
5. Fan Mode - You can set the fan mode
to adapt the cooling and noise level to the
environment.
The fan mode can be manually set from the
“Color” menu of the device.
For that, navigate to the “Setup” menu
selection at the bottom. When it is high-
lighted, press the OK button for two sec-
onds and then use the Jog-Wheel to scroll
between values.
The table below shows the available options:
FLEX: Minimum of approx 1,300 rpm
when below 45 °C. Increases linearly
to approx 2,900 rpm at 58 °C
FAST: Always at max (approx 2,900
rpm)
SLOW: Always at min (approx 1,300
rpm)
OFF: Fan off until 77 °C, then turns on
at minimum speed of approx 1,300
rpm, and turns back off when the
temperature drops below 60 °C
FLX2: Fan off until 45 °C, turns on and
linearly increases to a maximum of
approx 2,900 rpm at 58 °C *
*Note: Critical temperature for a lamp module is 80 °C,
upon which it is shut off. Covering the lamp unit even par-
tially is not recommended, as it will increase the chances
of it reaching this critical temperature. Consult with Digital
Sputnik technical support if you have questions about a
custom application in extreme conditions.