Specifications

Other brands
CODAN NGT
Select CODAN in Setup. By convention TRX-Manager adresses the CODAN NGT's Channels by
their name (or label) from "01" to "99". Consequently, you have to rename all names by using
only 01 02 03... 99.
RACAL 6790
Select RACAL in Setup and fill in the Address field.
After you restart TRX-Manager, press the CATbutton ( CAT control ) in order to activate
remote control. This mode takes over control of the radio (there is NO manual control from the
radio controls while in this mode, not even the tuning dial !). CAT ON is absolutely required
for scanning or controlling the receiver from the Monitoring; however, tuning a spot
(using DXor Web-Cluster) tuning a SW Station does not require activating CAT mode. Also
displaying the current frequency/mode of the receiver does not require CAT ON.
By default TRX-Manager uses CW mode with BFO. Prior to use the CW mode, you have to
set up Offset at least ONCE by setting up Pitch from the Edit/Pitch submenu or from the
Preferences/Transceiver dialog. Later on TRX-Manager retains the correct Pitch. Offset is
positive by default; to set up a negative Offset please use the CW REVerse mode.
To use CW with a central frequency, you have to define a nul Offset (Pitch = 0) from the
Preferences/Transceiver dialog.
ISB mode is not supported by TRX-Manager as a standard mode. However, by convention,
TRX-Manager displays ISB mode as FSK. Consequently, to set up ISB mode, select FSK from
TRX-Manager...
Bandwidth is selectable for CW AM FM. 3 selections are available : WID (Wide) MED
(Medium) NAR (Narrow). TRX-Manager polls the receiver for installed filters and selects the
most approriate for each mode.
OMNI-RIG
OMNI-RIG is a COM component for transceiver/receiver CAT control written by Alex VE3NEA.
It supports many rigs (some not currently supported by TRX-Manager) and multiple programs
at the same time. TRX-Manager does not install OMNI-RIG on your computer. You must
downloadand install/update OMNI-RIG before you configure TRX-Manager for OMNI-RIG
(OmniRig's Setup may be included in the recent CDs ). For more information about OmniRig and
its installation, please see the Omni-Rig's web site.
From the TRX-Manager's Setup dialog, select OMNI-RIG1 or OMNI-RIG2 depending on your
Setup for Omni-Rig. If necessary click Configure to configure Omni-Rig. Restarting
TRX-Manager is mandatory in order to set up the TRX-Manager's interface.
CW and DIG modes: through OmniRig, CW_U and DIG_U are selected by default for CW and
Page 93