Specifications

The roll-off value for DSP is fixed to 200 Hz.
BFO (CW)
The BFO may be adjusted by using the Pitch function of TRX-Manager (Edit/Pitch) or from the
Preferences/Transceiver dialog. The default value is 600 Hz.
AF and Line levels
These levels are adjustable from the Levels window (Sub receiver level = Line level).
AGC
AGC is adjustable from the Levels window (1=Slow, 2=Medium, 3=Fast, Off not supported).
Argonaut V
Please select Argonaut from Setup and check RTS and DTR. Communication Speed must be
set to 1200 bauds.
TRX-Manager supports the Argonaut V transceiver and almost all programmable functions
including DSP filtering, Keyer Speed, NB, Attenuator ; the Argonaut V's protocol does not
support setting of AF & RF levels.
Jupiter
Please select Jupiter from Setup and check RTS and DTR. Communication Speed must be set
to 57600 bauds.
TRX-Manager supports the Jupiter transceiver and almost all programmable functions including
DSP filtering, NB, NR, Attenuator, AF, RF, SQ Levels...
Page 90