Specifications
While the sub receiver has the control, you may use the Edit/VFO window ( F2) or the
Up/Down buttons, the keypad and the slider of the Monitoringto set a frequency but the
Command Panel is disabled. To toggle from Memory mode to VFO (and vice versa), please use
the C button of the Monitoring.
The Band Scope has the ability to scan the sub receiver.
Generally most of the commands or the modules affect the main receiver only. Consequently,
when the sub receiver has the control, some informations (RX TX frequencies) or functions
may be wrong or may have inexpected results.
Memory channels operation
TRX-Manager supports the 301 channels of the TS-2000 including Labels and the memory
Group numbers (100 channels for TS-480 - 110 channels for TS-590S/SG).
Reverse parameter of the Channel window is related to Mode (CW-R, FSK-R),
Skip parameter skips a channel during a scanning (Lockout),
TS-2000
Channel 300 is the Call channel (it is not editable from TRX-Manager),
RX-TX Split is converted into Repeater Shift in FM mode, you may select the groups to be
recalled in memory mode from the Channel window,
Group numbers are displayed for each channel under the Scancolumn of the Channels window.
When you change a group number from the computer, the TS-2000's display takes this change
into account but the change is not effective ! You have to boot TS-2000 in order to make the
new group numbers effective,
It is not possible to edit a channel opened in the sub-receiver : please deselect the memory
mode of the sub-receiver before editing any channel.
See also : Channels overview
Automatic configuration of the DSP Filters
TRX-Manager automatically configures the DSP filters according to the values defined under
the Transceiver tab of the Preference submenu. Please check DSP Enabled in order to
activate the automatic configuration and take care to fill in the desired values for the Pitch
and repeaters Shifts.
If you own a TS-480 and the additional SSB narrow filter is installed, you may check the
NAR1 option: the corresponding filter will be associated with TRX-Manager's Narrow selection
(SSB/FM/AM only - selected by DSP in CW).
TS-590S
TRX-Manager memorizes the Filters A/B for each VFO. This is particulary useful in Split mode while
you use the TF-Set function. To use this function you have to initialize the desired Filter for each
VFO at startup either from the Levels window or directly from the transceiver and engage the AUTO
Mode/Filter switching .
See also : Modes and filters
Levels window
Page 73