Specifications

Operation with FT-767GX
This section applies for use with the FT-767GX Transceiver. You may run the program as
follow:
CAT Control Mode
To be under CAT control you must press the CAT button (located on the toolbar) or the F9
key. When the transceiver is under CAT Control you will not be able to set things from the
transceiver's front panel (as frequencies, mode, functions, etc.) In order to gain manual
control, you have to press the CAT button on the toolbar or F9 again to release the CAT
control mode.
The CAT control is only active when the CAT button looks as if is depressed. The CAT light on
your transceiver's front panel will also be illuminated when under CAT control. CAT control is
released upon program shutdown, but it is a good idea to make it a habit when you shutdown
the software BEFORE shutting turning off the transceiver.
However you may set a DX Spot or a SWL frequency without setting on the CAT Mode.
The Monitoring shows a variable tuning control.
Warning
During CAT Control, manual control is NOT possible!
Limitations
No S-Meter function
Not available through the FT-767GX CAT interface, therefore the Band Scope is not available.
Filters
Filters are not controllable via the CAT system.
Memory channels
CTCSS tone data are supported (FT-8 tone squelch unit required). However, you have to
manually switch on the T Enc or the T SQL function from the front panel. Warning : if you
don't own the FT-8 unit do not check Enc or Dec !
Tuner
Tuner functions and status are not controllable via the CAT system.
Page 56