Specifications
Please select ICOM for the Command to field; the command is typed in using the format
required by the manual but without Preamble + Addressees (FEFEXXYY) and without the End
of message code (FD) : only the command, the sub command and the data area are required
Multiple commands
Multiple commands (in a chain) are possible; the multiple commands are separated by a slash
(/).
Commands to the remote station (SERVER)
When controlling a remote station using TRX-Manager, you can send commands to the
SERVER station using TRX-Command. Macro commands (same syntax as above) sent to the
SERVER station are ignored by the CLIENT station.
To send a command to a Remote serial port other than the transceiver in use, please select
RS232 (Rem) for the Command to field.
Customized sliders
Same syntax as above but includes digits for the slider. The command string includes as many
* (joker) as the number of digits required by the protocol. Min and Max values are always
decimal starting from 0 to 255 (generally).
Example
ICOM : Command for AF gain is 14010000 to 14010255. Syntax = 1401**** (4 digits required)
with Min=0 and Max=255
KENWOOD : Command for AF gain is AG0000 to AG0255. Syntax is AG0*** (3 digits required) with
Min=0 and Max=255
Page 388