Specifications

available with a registered version of the program).
1.4) Packet control only
Address of the server station : 0 to 9 (the SERVER station must have an address so that
several stations can be operated remotely on the same packet frequency)
Auto Information : if checked the remote transceiver will notify and confirm to the client
station each change of frequency, mode... and S-Meter readings
To save resources on SERVER computer, please let Traffic Display unchecked (the
Terminal will not display any data coming from the CLIENT station).
Terminal (TNC tab): set the function buttons #9 and #10 (S1 S2). The Terminal will be
automatically launched and the corresponding S1 S2 messages will be sent to the TNC 5
seconds after startup. These messages may be useful for configuring your TNC or
establishing the connection automatically (S1 S2 buttons only appear once the
SERVEUR mode and REMOTE Control are activated)
Setting up the base station (CLIENT)
2.1) Setup panel
No setup is required under the Parameters/Setup dialog to run the standard mode of remote
control if you are using the Remote TRX window (an Alternative Setup using the Monitoring
for remote control is explained under Remote Control Operation).
2.1) Remote TRX window (Setup tab)
1.
CLIENT selected
2.
Protocol: Packet, UDP or TCP (same as the one defined from the SERVER computer)
3.
UPD: a valid listening port (1001 is the default) for the SERVER and a valid listening port
for the CLIENT (1002 is the default),
4.
TCP: a valid (and unique) port for a TCP connection (1001 is the default)
5.
TCP or UDP : IP address of the SERVER computer
6.
Packet: see specific settings below
2.2) Optional settings
1.
Auto connect : if this option is checked, connection is established and the password is
sent as soon as you engage the Remote Control Mode.
2.
Watch dog : CLIENT disconnects if no packet is received after the specified delay and
sends a WD frame to maintain the connection ; it is mandatory you set up CLIENT with the
same option and the same delay.
3.
Password for the connection to the SERVER computer
4.
Remote scanning (CLIENT) : if this option is checked, the Monitoring's Up/Down button
engage a scanning controlled from the SERVER station. If your connection is fast enough,
this provides a smooth scanning. If your connection is slow or unreliable, it is preferable
you let this case unchecked.
5.
Synchro: If checked, the Remote transceiver activates the synchro ports
defined from the CLIENT instance of TRX-Manager (SteppIR synchro excepted).
2.3) Packet only
1.
Address of the server station: 0 to 9
2.
Flow control (CLIENT/Packet): the flow control reduces the amount of commands sent
during the specified delay (in seconds). This option is useful if your connection can not
handle the data flow.
Page 190